| Item |
Characteristics |
| Operating
Temperature Range(℃) |
-40~+85(16~100V),-25~+85(160~450V) |
| Rated
Voltage Range(V) |
16-450 |
| Capacitance
range(μF) |
33-68000 |
| Capacitance
Tolerance(25℃,120Hz) |
-10%~+50% |
| Leakage
current(μA) |
3CV
MAX (at 25℃, after 5 minutes)
C: Nominal Capacitance(μF) V:Rated Voltage(V) |
| Dissipation
Factor(25℃,120Hz) |
| Rated
voltage(V) |
16-25 |
35-63 |
80-350 |
400-450 |
| Cap(μF) |
3300-10000 |
15000-33000 |
47000-68000 |
1000-10000 |
15000-33000 |
47-10000 |
33-470 |
| tanδ |
0.35 |
0.50 |
0.75 |
0.25 |
0.35 |
0.20 |
0.25 |
|
| Temperature
Stability(120Hz) |
| Rated
voltage(V) |
16-100 |
160-250 |
315-450 |
| Impedance
Ratio |
Z-25℃/Z+20℃ |
3 |
3 |
8 |
| Z-40℃/Z+20℃ |
12 |
- |
- |
|
| Load
Life(85℃) |
| Time |
1000
hours |
| Leakage
Current |
Not
more than the specified value. |
| Capacitance
Change |
within
±20% of the initial value. |
| Dissipation
Factor |
Not
more than 200% of the specified value. |
|
| Shelf
Life(85℃) |
| Time |
1000
hours |
| Leakage
Current |
Not
more than the specified value. |
| Capacitance
Change |
within
±20% of the initial value. |
| Dissipation
Factor |
Not
more than 200% of the specified value. |
After test:UR to be