| Item |
Characteristics |
| Operating
Temperature Range(℃) |
-40-+85 |
| Capacitance
Tolerance(20℃,
120Hz) |
±20% |
| Leakage
Current(μA) |
0.01CV or 3
whichever is greater. (at 20℃,after
2 minutes)
C: Nominal Capacitance(μF) V:Rated Voltage(V)
|
| Dissipation
Factor(20℃,120Hz) |
| Rated
voltage(v) |
4 |
6.3 |
10 |
16 |
25 |
35 |
50 |
| tanδ |
φ3-φ6.3 |
0.35 |
0.24 |
0.20 |
0.16 |
0.14 |
0.12 |
0.10 |
| φ8 |
0.39 |
0.28 |
0.24 |
0.16 |
0.14 |
0.12 |
0.10 |
|
| Temperature
Stability(120Hz) |
| Rated
voltage(v) |
4 |
6.3 |
10 |
16 |
25 |
35 |
50 |
| Impedance
Ratio |
z-25℃/z+20℃ |
6 |
4 |
3 |
2 |
| z-40℃/z+20℃ |
16 |
10 |
8 |
6 |
4 |
|
| Load
Life(+85℃) |
| Time |
1000hours |
| Leakage
current |
Not
more than the specified value. |
| Capacitance
change |
within±20%
of initial value |
| Dissipation |
Not
more than 200% of the specified value. |
|
| Shelf
Life(+85℃) |
500hours. No
voltage appiled. After test:UR to be applied
for 30 minutes, 24 to 48 hours before measurement.
|