| Item |
Characteristics |
| Operating
Temperature Range(℃) |
-40~+105(≧160V
,-25~+105) |
| Capacitance
Tolerance(20℃,120Hz) |
±20%
|
| Leakage
current(μA) |
0.01CV
or 1.5mA whichever is smaller (at 20℃
,after 5 minutes)
C:Nominal Capacitance(μF) V:Rated Voltage(V) |
| Dissipation
Factor(20℃,120Hz) |
| Rated
voltage(v) |
16 |
25 |
35 |
50 |
63-100 |
160-400 |
450-500 |
| tanδ |
0.50 |
0.40 |
0.35 |
0.30 |
0.20 |
0.15 |
0.20 |
|
| Temperature
Stability(120Hz) |
| Rated
voltage(v) |
16~100
|
160~200
|
250~500
|
| Impedance
Ratio |
Z-25℃/Z+20℃ |
4
|
4
|
4
|
| Z-40℃/Z+20℃ |
15
|
-
|
-
|
|
| Load
Life(+105℃) |
| Time |
2000
hours |
| Leakage
Current |
Not
more than the specified value. |
| Capacitance
Change |
Within
±20% of the initial value. |
| Dissipation
Factor |
Not
more than 200% of the specified value. |
|
| Shelf
Life(+105℃) |
1000hours,
No voltage applied.the capacitor shall meet the specified
limits for "Load Life" . After test:UR
to be applied for 30 minutes, 24 to 48 hours before measurement.
|