| Item |
Characteristics |
| Operating
Temperature Range(℃) |
-40~+85(450~500WV:-25~+85) |
| Capacitance
Tolerance(20℃,120Hz) |
±20%
|
| Leakage
current(μA) |
0.01CV
or 1.5mA whichever is smaller(at 20℃
,after 5 minutes)
C:Nominal Capacitance(μF) V:Rated Voltage(V) |
| Dissipation
Factor(20℃,120Hz) |
| Rated
voltage(v)
Cap(μF)
|
10-16 |
25 |
35-50 |
63 |
80-100 |
| ~2700 |
- |
- |
0.20 |
0.15 |
0.15 |
| 3300-4700 |
- |
0.35 |
0.25 |
0.20 |
0.15 |
| 5600-6800 |
0.40 |
0.35 |
0.30 |
0.20 |
0.20 |
| 8200~ |
0.40 |
0.35 |
0.35 |
0.25 |
- |
| Rated
voltage(v)
ΦD(mm)
|
160-200 |
250-500 |
| 35 |
0.12 |
0.15 |
|
| Temperature
Stability(120Hz) |
| Rated
voltage(v) |
10 |
16-35 |
50-100 |
160-200 |
250-400 |
450~500 |
| Impedance
Ratio |
Z-25℃/Z+20℃ |
5 |
4 |
3 |
3 |
4 |
4 |
| Z-40℃/Z+20℃ |
18 |
15 |
10 |
6 |
8 |
- |
|
| Load
Life(+85℃) |
| Time |
2000
hours |
| Leakage
Current |
Not
more than the specified value. |
| Capacitance
Change |
Within
±20%
of the initial value. |
| Dissipation
Factor |
Not
more than 200% of the specified value. |
|
| Shelf
Life(+85℃) |
| Time |
1000
hours |
| Leakage
Current |
Not
more than the specified value. |
| Capacitance
Change |
Within
±15%
of the initial value. |
| Dissipation
Factor |
Not
more than 150% of the specified value. |
After
test:UR to be applied for 60 minutes, 24 to 48
hours before measurement.
|