| Item |
Characteristics |
| Operating
Temperature Range(℃) |
-55~+105 |
-40~+105 |
| Rated
Voltage Range(V) |
6.3~100 |
160~450 |
| Capacitance
Tolerance(20℃,120Hz) |
±20%
|
| Leakage
current(μA) |
0.01CV
or 3 whichever is greater.(at 20℃,after 2 minutes)
|
|
C:Nominal Capacitance(μF) V:Rated
Voltage(V)
|
| Dissipation
Factor(20℃,120Hz) |
| Rated
voltage(v) |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
160~250 |
315~450 |
| tanδ |
0.28 |
0.24 |
0.20 |
0.16 |
0.14 |
0.12 |
0.10 |
0.08 |
0.20 |
0.24 |
when nominal capacitance
is over 1000uF tanδ shall be added 0.02 to
the listed value with increase of every 1000 uF
|
| Temperature
Stability(120Hz) |
| Rated
voltage(v) |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
| Impedance
Ratio |
Z-25℃/Z+20℃ |
5 |
4 |
3 |
2 |
| Z-40℃/Z+20℃ |
10 |
8 |
6 |
4 |
3 |
| Rated
voltage(v) |
160~250
|
315~450
|
| Impedance
Ratio |
Z-25℃/Z+20℃ |
4
|
| Z-40℃/Z+20℃ |
15 |
10 |
|
| Load
Life(105℃) |
| Time |
2000
hours |
| Leakage
current |
Not
more than the specified value. |
| Capacitance
Change |
within
±20% of the initial value. |
| Dissipation
Factor |
Not
more than 200% of the specified value. |
|
| Shelf
Life(105℃) |
| Time |
1000
hours |
| Leakage
current |
Not
more than the specified value. |
| Capacitance
Change |
within
±20% of the initial value. |
| Dissipation
Factor |
Not
more than 200% of the specified value. |
After test:UR