| Item |
Characteristics |
| Rated
Voltage Range(v) |
350~450 |
| Operating
Temperature Range(℃) |
+40~+105 |
| Capacitance
Tolerance(20℃,120Hz) |
±20% |
| Leakage
current(μA) |
0.01CV
or 5mA,whichever is smaller. (at 20℃,after 5 minutes)
C:Nominal capacitance (μF) V:Rated voltage(V) |
| Dissipation
Factor(20℃,120Hz) |
0.15 |
| Load
Life(+105℃) |
| Time |
5000hours |
| Leakage
current |
Not
more than the specified value |
| Capacitance
Change |
Within
±15% of the initial value |
| Dissipation
Factor |
Not
more than 175% of the specified value |
|
| Shelf
Life(+105℃) |
| Time |
1000hours |
| Leakage
current |
Not
more than the specified value |
| Capacitance
Change |
Within
±15% of the initial value |
| Dissipation
Factor |
Not
more than 175% of the specified value |
*After Test: UR
to be applied for 30 minutes,12 to 24 hours before measurement
|