| Item |
Characteristics |
| Operating
Temperature Range(℃) |
-40~+85 |
| Capacitance
Tolerance(20℃,120Hz) |
±20%
or ±10% |
| Leakage
current(μA) |
0.006CV
or 0.5 whichever is greater.(1 minute,at 20℃)
0.002CV or 0.3 whichever
is greater.(2 minutes, at 20℃)
C:Nominal Capacitance (μF) V:Rated Voltage(V)
|
| Dissipation
Factor(20℃,120Hz) |
| Rated
voltage(V) |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
| tanδ |
~Φ10x12.5 |
0.18 |
0.15 |
0.12 |
0.08 |
0.08 |
0.08 |
0.07 |
0.07 |
| Φ10x12.5~ |
0.21 |
0.17 |
0.14 |
0.12 |
0.12 |
0.10 |
0.08 |
0.08 |
|
| Temperature
Stability(120Hz) |
| Rated
voltage(V) |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
| Impedance
Ratio |
Z-25℃/Z+20℃ |
4 |
3 |
2 |
1.5 |
| Z-40℃/Z+20℃ |
8 |
6 |
4 |
3 |
|
| Load
Life(+85℃) |
| Time |
2000
hours |
| Leakage
Current |
Not
more than the specified value. |
| Capacitance
change |
Within
±15% of the initial value. |
| Dissipation
Factor |
Not
more than 150% of the specified Value. |
|
| Shelf
Life(+85℃) |
1000hours. No voltage appiled.
After test:UR to be applied for 30 minutes, 24
to 48 hours before measurement.
|