| Item |
Characteristics |
| Operating
Temperature Range(℃) |
-40~+85 |
| Capacitance
Tolerance(20℃,120Hz) |
±20% |
| Leakage
Current(μA) |
| Rated
Voltage(V) |
6.3-100 |
160-450 |
0.03cv
or 4 whichever is greater(at 20℃,after 1 minute)
0.01cv or 3 whicheveer is greater(at 20℃, after
2 minutes) |
CV≤1000:0.1
CV+40(at 20℃, after 1 minute)
CV>1000:0.04 CV+100(at 20℃, after 1 minute) |
|
| Dissipation
Factor(20℃,120Hz) |
| Rated
Voltage(v) |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
160 |
200 |
250 |
315 |
350 |
400 |
450 |
| tanδ |
0.28 |
0.24 |
0.20 |
0.16 |
0.14 |
0.12 |
0.10 |
0.08 |
0.20 |
0.20 |
0.20 |
0.24 |
0.24 |
0.24 |
0.24 |
when nominal capacitance is
over 1000uF tanδ shall be added 0.02 to the
listed
value with increase of every 1000 uF
|
| Temperature
Stability(120Hz) |
| Rated
Voltage(V) |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
160 |
200 |
250 |
315 |
350 |
400 |
450 |
| Impedance |
Z-25℃/Z+20℃ |
5 |
4 |
3 |
2 |
4 |
| Z-40℃/Z+20℃ |
12 |
10 |
8 |
5 |
4 |
3 |
15 |
10 |
|
| Load
Life(+85℃) |
| Time |
2000hours |
| Leakage
current |
Not
more than the specified value |
| Capacitance
change |
within
±20% of the initial value |
| Dissipation
Factor |
Not
more than 200% of the specified value |
|
| Shelf
Life(+85℃) |
1000
hours, No voltage applied.After test:UR to be applied
for 30 minutes,24 to 48 hours before measurement |