| Item |
Characteristics |
| Operating
Temperature Range(℃) |
-40~+85 |
| Capacitance
Tolerance(20℃,120Hz) |
±20% |
| Leakage
current(μA) |
| Rated
Voltage(V) |
6.3-100 |
160-450 |
| |
0.01CV
or 3 whichever is greater.( at 20℃,after 2 minutes) |
0.06CV+10(at
20℃,after 2 minutes ) |
C:Nominal capacitance (μF)
V:Rated voltage (V)
|
| Dissipation
Factor(20℃,120Hz) |
| Rated
Voltage (V) |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
160 |
200 |
250 |
350 |
400 |
450 |
| tanδ |
0.22 |
0.19 |
0.16 |
0.14 |
0.12 |
0.10 |
0.09 |
0.08 |
0.12 |
0.12 |
0.15 |
0.15 |
020 |
0.23 |
when nominal
capacitance is over 1000uF tanδ shall be added
0.02 to the listed
value with increase of every 1000 uF
|
| Temperature
Stability(120Hz) |
| Rated
Voltage (V) |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
160 |
200 |
250 |
350 |
400 |
450 |
| Impedance
Ratio |
Z-25℃/Z+20℃ |
4 |
3 |
2 |
3 |
6 |
| Z-40℃/Z+20℃ |
8 |
6 |
4 |
3 |
8 |
|
|
| Load
Life(85℃) |
| Time |
2000
hours. |
| Leakage
Current |
Not
more than the specified value. |
| Capacitance
Change |
Within
±20% of the initial value. |
| Dissipation
Factor |
Not
more than 200% of the specified value. |
|
| Shelf
Life(85℃) |
1000hours.
No voltage appiled, After test:UR to be applied
for 30 minutes, 24 to 48 hours before measurement.
|